Hammond Power Solutions
Founded in 1917, HPS is North America's largest manufacturer of dry-type transformers, with plants in Canada, the United States and Mexico. It develops more than 5,200 designs a year and runs a network of 11 distribution centers and 7 warehouses across North America.
Its portfolio spans control transformers, low- and medium-voltage distribution, power quality, mini power centers and custom-built solutions, serving oil and gas, petrochemical, mining, renewable generation and offshore drilling platforms.
Strengths
1917
Founded
5,200
New designs per year
750,000+
Units shipped (2022)
<1%
Returns from manufacturing defects
Specification table
Specification table
HPS product photo — pending
Technical spec Model · HPS Titan™ N
- Type
- Epoxy/silica encapsulated transformer
- Range / Standard
-
- Single- and three-phase
- cUL listed
- OSHPD certified
- ABS type approval for marine use
- T3C/T3A temperature classification
- copper windings
- Application
- Petrochemical, marine, industrial, oil and gas, mining and wastewater; shields against airborne contaminants and moisture ingress
- Detail
-
- Removable hinged door
- factory-fitted grounding terminals
HPS product photo — pending
Technical spec Model · HPS Millennium™ E
- Type
- Medium-voltage transformer, VPI system
- Range / Standard
-
- Three-phase up to 15 MVA, 34.5 kV, 175 kV BIL
- single-phase up to 5 MVA
- VPI up to 35 kV class
- 50, 60 or 50/60 Hz
- DOE 2016 / NRCan 2019
- Application
- Power distribution substations, power generation, offshore drilling platforms, industrial processes and renewable energy systems
- Approvals
-
- CSA C22.2 No. 47
- CSA C9-02
- UL 1562
- IEEE-C57.12.01/.51/.70/.91
- CSA 802.2-12
- DOE 10 CFR Part 431 (2010 or 2016)
- NRCan SOR/2018-201 Amd. 14
- ON Reg. 404/12 (2018)
- IEC 60076 (on request)
- IBC 2018 seismic qualification (ASCE 7-16)
- Options
- Air terminal chamber (ATC), infrared viewing windows, lift-out hinged doors
HPS product photo — pending
Technical spec Model · HPS TruWave™
- Type
- Active harmonic filter
- Range / Standard
-
- Cuts harmonic distortion below 5% per IEEE-519
- 98% operating efficiency
- 208–480 VAC, +12%/−15% (600 VAC with autotransformer)
- 50 or 60 Hz
- three-phase, 3-wire plus ground
- Application
- Oil and gas, mining, chemical processing, data centers, HVAC, material handling, pulp and paper, wastewater treatment
HPS product photo — pending
Technical spec Model · HPS Centurion™ P
- Type
- Passive harmonic filter
- Range / Standard
-
- 480 VAC or 600 VAC ±10%
- 480 VAC input: 8–632 A (5–500 HP); 600 VAC: 6–505 A (5–500 HP)
- 5th, 7th, 11th, 13th harmonic mitigation
- ≥99% efficiency at full load
- power factor >95%
- 150% overload for 1 minute
- 50 °C ambient
- open or type 3R enclosure
- cUL listed (E61431)
- Application
- Oil and gas, irrigation, wastewater, food processing, HVAC, pharmaceutical, steel, pulp and paper, automation
Other product families
HPS Millennium™ G Medium-voltage transformer 2,400 to 4,160 V · up to 5 kV class · VPI system View full specification
Technical spec Model · HPS Millennium™ G
- Type
- Medium-voltage transformer
- Range / Standard
-
- 2,400 to 4,160 V
- up to 5 kV class
- VPI system (vacuum pressure impregnation)
- type 3R enclosure
- DOE 2016 / NRCan 2019
- UL listed, CSA certified
- Application
- Commercial, industrial and renewable
HPS Centurion™ R Line reactor 50/60 Hz · rated 0.5 to 1,250 HP (0.37–932 kW) View full specification
Technical spec Model · HPS Centurion™ R
- Type
- Line reactor
- Range / Standard
-
- 50/60 Hz
- rated 0.5 to 1,250 HP (0.37–932 kW)
- Application
- Protects AC motors and drives; extends breaker and motor life; lowers motor noise and operating temperature
HPS Centurion™ S SineWave motor-protection filter 380–480 V and/or 600 V · rated current 9 A to 600 A View full specification
Technical spec Model · HPS Centurion™ S
- Type
- SineWave motor-protection filter
- Range / Standard
-
- Rated voltage 380–480 V and/or 600 V
- rated current 9 A to 600 A
- max voltage harmonic distortion 5%
- cULus listed
- open or type 3R enclosure
- Application
- Reshapes a VFD's PWM output into a sine wave; oil and gas, irrigation, wastewater, food, HVAC, pharmaceutical, steel, pulp and paper, automation
HPS Centurion™ D1 dV/dT filter system up to 600 V · motor cable up to 1,000 ft View full specification
Technical spec Model · HPS Centurion™ D1
- Type
- dV/dT filter
- Range / Standard
-
- System voltage up to 600 V (480–600 V applications)
- voltage drop below 3%
- motor cable length up to 600 ft standard, optional up to 1,000 ft
- 130 °C insulation (2–54 A), 180 °C (>55 A)
- cUL listed
- open or type 3R enclosure
- Application
- Between VFDs and motors on long cable runs; oil and gas and the rest of the Centurion line
HPS Sentinel™ Solar Duty Distribution transformer for solar generation 15 kVA to 1,000 kVA · 60 Hz · 10 kV BIL View full specification
Technical spec Model · HPS Sentinel™ Solar Duty
- Type
- Distribution transformer for solar generation
- Range / Standard
-
- Three-phase 15 kVA to 1,000 kVA (custom ratings on request)
- 60 Hz
- 150 °C temperature rise, 220 °C insulation class, 10 kV BIL
- copper or aluminum windings
- bidirectional label declaration
- optional K-factor for non-linear loads
- UL approved, CSA certified
- DOE 10 CFR Part 431 (2016), SOR/2018-201 (NRCan 2019), ON Reg. 404/12
- Application
- Voltage adjustment between the solar generation system and the utility
Product line
Product line
- Transformers
- Control · encapsulated · wound · energy-efficient distribution · isolation · three-phase autotransformers · VPI and Cast Coil
- Additional families
- HPS Sentinel™ · Sentinel™ K (K-factor) · Sentinel™ H (harmonics) · Fortress™ (encapsulated) · Express L™ · Imperator™ (control) · Spartan™ (control) · Tribune™ E (drive isolation) · PowerPlus™ (mini power center) · Universal™ (buck-boost) · 2A-Series and 3A-Series autotransformers · three-phase autotransformers from 3 to 500 kVA
- Other
- Line reactors and dV/dT filters · active harmonic filters · mini power centers
- Cross-cutting technical features
- K-factor · harmonic mitigation · unique input and output voltages · low inrush current · 6-, 12-, 18-, 24- and 36-pulse isolation · rectifier · land drilling · marine · triplex · unit substation